Installation Guide
Tools Needed:
- Drill with hole saw attachment
- Screwdrivers (flat and Phillips)
- Level
- Tape measure
- Vacuum cleaner
- Sealant gun
Step-by-Step Installation
- Choose Installation Location: Select a location with proper wall support, away from direct sunlight and heat sources, with adequate clearance for airflow.
- Prepare Wall Opening: Cut a precise hole in the wall according to the unit's dimensions, ensuring proper slope for drainage.
- Install Mounting Bracket: Securely mount the bracket to the wall using appropriate anchors and screws for your wall type.
- Connect Electrical Wiring: Connect to a dedicated 230V, 50Hz circuit with proper grounding. Follow local electrical codes.
- Install Drainage System: Connect the condensate drain hose with proper slope to ensure water drainage away from the building.
- Mount the Unit: Carefully lift and secure the air conditioner onto the mounting bracket, ensuring it's level and stable.
- Seal Gaps: Apply weatherproof sealant around the unit to prevent air leaks and insect entry.
- Test Operation: Run the unit through all modes and settings to verify proper installation and operation.
Specifications
Model Series | WHA Series |
Type | Split System Air Conditioner |
Color | White / Silver |
Cooling Capacity | 12,000 BTU/h |
Heating Capacity | 13,000 BTU/h |
Noise Level (Indoor/Outdoor) | 24 dB / 52 dB |
Control Type | Manual Controls with LED Display |
Energy Rating | A++ (Highly Efficient) |
Power Requirements | 230V, 50Hz, 15A |
Dimensions Indoor Unit (HxWxD) | 29 x 79 x 21 cm |
Dimensions Outdoor Unit (HxWxD) | 54 x 76 x 28 cm |
Refrigerant | R32 Eco-Friendly |
Room Coverage | Up to 35 m² |
Warranty Information
- Full Warranty: 2 years parts and labor
- Compressor Warranty: 5 years on inverter compressor
- Additional Coverage: Optional extended warranty available
For warranty service, contact Whirlpool Customer Service at 1-800-253-1301 or visit Whirlpool.com
Key Features
6th Sense Technology
Advanced sensors automatically detect room conditions and adjust cooling/heating performance for optimal comfort and energy efficiency.
Inverter Compressor
The variable speed inverter compressor adjusts power consumption based on cooling demand, reducing energy usage and maintaining consistent temperature.
Auto Restart
Automatically resumes previous settings after power interruption, ensuring uninterrupted comfort without manual resetting.
Sleep Mode
Gradually adjusts temperature throughout the night for optimal sleeping conditions while minimizing energy consumption.
Turbo Mode
Rapid cooling/heating function that quickly reaches desired temperature when maximum performance is needed.
Anti-Bacterial Filter
Built-in filter captures dust, pollen, and bacteria, providing cleaner and healthier air while reducing allergens.
Operating Modes
Cool Mode
Standard cooling operation with adjustable temperature settings from 16°C to 30°C
Heat Mode
Heating operation for colder seasons with temperature range from 16°C to 30°C
Dry Mode
Dehumidification function that removes excess moisture while maintaining comfortable temperature
Fan Mode
Air circulation only with multiple fan speed options (Low, Medium, High, Auto)
Auto Mode
Intelligent mode that automatically selects cooling or heating based on room temperature
Eco Mode
Energy-saving operation that optimizes performance for reduced power consumption
Troubleshooting
Problem | Possible Cause | Solution |
---|---|---|
Unit not starting | Power issue, remote control batteries, timer setting | Check power supply, replace remote batteries, check timer settings |
Poor cooling/heating | Dirty filters, blocked vents, incorrect temperature setting | Clean filters, ensure proper airflow, set appropriate temperature |
Water leakage | Clogged drain pipe, improper installation slope | Clear drain pipe, ensure proper installation angle |
Unusual noises | Loose parts, debris in fan, vibration | Tighten mounting, clean fan blades, check installation stability |
Frozen coils | Dirty filters, low refrigerant, restricted airflow | Clean filters, check for airflow obstructions, contact service |
Remote not working | Dead batteries, signal obstruction, distance | Replace batteries, ensure line of sight, move closer to unit |
Error Codes
- E1: Room temperature sensor error - Check sensor connection
- E2: Evaporator temperature sensor error - Contact service center
- E3: Communication error between units - Check wiring connections
- E4: High pressure protection - Clean outdoor unit, check airflow
- E5: Low pressure protection - Check for refrigerant leaks
- E6: Compressor overload - Allow unit to cool down, check voltage
Manual Downloads
Current Model Manuals
WHA12000
12,000 BTU 6th Sense AC
WHA18000
18,000 BTU 6th Sense AC
WHA9000
9,000 BTU 6th Sense AC
WHA24000
24,000 BTU 6th Sense AC
Popular Previous Models
WHA10000
10,000 BTU Standard AC
WHA15000
15,000 BTU Inverter AC
WHA8000
8,000 BTU Window AC
WHA22000
22,000 BTU Dual Zone AC